檢修母線通道前,須先將配電柜斷電,并掛上“有人操作,不準(zhǔn)合閘”的標(biāo)牌,并派專人監(jiān)護(hù)。檢修工作開始前,應(yīng)檢查并放電,接地棒使用后,可進(jìn)行相間回路和可靠接地。
Before the maintenance of the bus passage, the power distribution cabinet must be cut off first, and the sign "No switching on, no switching on" must be hung, and a special person must be assigned for monitoring. Before maintenance, check and discharge. After using the grounding rod, the interphase circuit and reliable grounding can be carried out.
定期檢查母線槽各進(jìn)線端子電壓,確認(rèn)母線槽已完全切斷電源。經(jīng)常用軟刷、吸塵器或棉花擦拭母線槽上的灰塵。母線槽的總負(fù)載電流不得超過主母線電流或設(shè)計(jì)電流。
Regularly check the voltage of each incoming terminal of the bus duct, and confirm that the bus duct has completely cut off the power supply. Frequently wipe the dust on the bus duct with a soft brush, vacuum cleaner or cotton. The total load current of the bus duct shall not exceed the main bus current or design current.
檢查作業(yè)現(xiàn)場(chǎng)溫度。設(shè)備安裝使用后3個(gè)月內(nèi)檢查連接螺栓是否松動(dòng),1年后多面檢查,其余每3年完全檢查一次。
Check the temperature of the operation site. Check whether the connecting bolts are loose within 3 months after the equipment is installed and used. After 1 year, check the connection bolts on multiple sides, and check the rest every 3 years.
特別注意接頭的夾緊扭矩和表面清潔。如果結(jié)構(gòu)松動(dòng)或被污染,電阻會(huì)增加,過熱。即使是不平整的連接面也可能出現(xiàn)電弧現(xiàn)象。
Pay special attention to the clamping torque and surface cleanliness of the joint. If the structure is loose or polluted, the resistance will increase and overheat. Even uneven joint surfaces may be arced.

如果母線槽長(zhǎng)期運(yùn)行,應(yīng)少每年定期檢查以確保,然后檢查總負(fù)載電流不超過設(shè)計(jì)電流和主母線槽的額定電流。
If the bus duct operates for a long time, it shall be checked regularly at least every year to ensure safety, and then check that the total load current does not exceed the design current and the rated current of the main bus duct.
在維護(hù)母線槽之前,須檢查母線槽系統(tǒng)是否已斷電!切斷所有母線槽的電源!
Before maintaining the bus duct, check whether the bus duct system is powered off! Cut off the power supply of all bus ducts!
此外,該儀器用于測(cè)量導(dǎo)線中是否有電壓,在確認(rèn)母線槽系統(tǒng)未充電后,可進(jìn)行日常維護(hù),以防止高壓對(duì)操作人員造成傷害。
In addition, the instrument is used to measure whether there is voltage in the conductor. After confirming that the bus duct system is not charged, routine maintenance can be carried out to prevent high voltage from causing injury to operators.
雖然母線槽所承載的大電流可以滿足人們的用電需求,但在使用過程中還存在許多問題需要注意。在使用過程中應(yīng)定期進(jìn)行維護(hù)和檢查,以確保母線槽電流傳輸?shù)摹S胁幻靼椎牡胤綒g迎來我們這里
http://m.ymmgjx.net咨詢!
Although the large current carried by the bus duct can meet the power demand of people, there are still many problems that need attention in the use process. During use, regular maintenance and inspection shall be carried out to ensure the safety of bus duct current transmission. Welcome to us if you don't understand http://m.ymmgjx.net consulting service